Looking for: · Software · macOS · Amadeus Pro · Download (en) Click here to Download
Looking for:
· Software · macOS · Amadeus Pro · Download (en)

It is when the inactivity disconnection happens that differences occur, especially for. For a terminal inactivity disconnection pass by undetected by the user because as soon as. However, for Pro Printer is quite different. Pro Printer does not send any requests to the host;. So, once the ISDN link has been disconnected, no. To summarize, it is v ery important to understand that the printing mechanism sends data asynchronously. This is not specific to the Amadeus Selling Platform. For the purposes of this document, two types of ISDN devices are considered:.
In order to work correctly with Pro Printer 2. O the rwise, it. The connection to the PC can be. Devices not falling in any of those two categories are not considered in this document. Such devices. The following paragraphs will describe each of the possible ISDN configurations, as well as the problems.
After disconnection, the ISDN line is automatically reconnected. In this type of configuration, Pro Printer starting in v ersion 2. If it is down, Pro Printer. After this, Pro Printer will wait for the line to. When it is, it will reconnect to the DDIP.
This means that if the. In this case it can happen that the agent sends the print request to the host, but when the central system. The solution is to increase the ISDN inactiv ity timeout to a v alue that allows enough time for the. ISDN line by inactivity, so that the line is down and the ticket coming from the central system cannot.
The solution in this case is to only allow PCs to print to a Pro Printer connected to the same. This way, if the ISDN line is disconnected, when someone wants to print, he will have to issue a request. However, a variable period of time is required by Pro Printer to become fully reconnected to the print. This means that if the request causing the ISDN line to reconnect is the printout request itself, it.
Windows dial-up connections. However, it would not be exactly the same since the current version of. Pro Printer already includes some special treatment for modem dial-up connections. In such case, Pro Printer. In order to detect if the dial-up connection is established, Pro Printer queries the operating system to.
If the connection is down, Pro Printer will not try to connect. If it. In this type of configuration, potential problems and the ir solutions with the current version of Pro. Pro Printer needs to send a keep-alive packet in order to detect, in a reasonable amount of time, when. One keep-alive packet is sent every 10 minutes, so if the dial-up inactivity. If it is smaller, Pro Printer will detect when the.
ISDN line is disconnected, changing its internal state to disconnected. When the ISDN line becomes. If costs-sav ing is not an issue, it is recommended that the dial-up inactiv ity timer be disabled,. If cost-saving is a must, the n the dial-up inactivity timer can be enabled, with a timeout lower than In this case, Pro Printer will require two minutes to reconnect to the D. IP server after the. ISDN line is up again.
Printouts generated during that time may cause the print queue to stop. The solution is to increase the dial-up inactiv ity timeout to a v alue that allows enough time for. Note: this case should not happen, since inactivity timeouts in Windows dial-up networking are specified.
The solution in this case is to only allow any giv en PCs to print to a Pro Printer instance that is. This way, if the ISDN line is disconnected, when the user wants to print, he will have to. However, a variable period of time is required by Pro Printer to become fully reconnected to. This means that if the request causing the ISDN line to reconnect is the printout request.
This Windows component or o the r third party applications can be used to share one PC internet connection. For this configuration type, Pro Printer has to be installed in the same PC where the modem is. O the rwise Pro Printer would not be able to detect the dial-up connection state and will not behave correctly. The uninstall has the same look and. Select the previous version you wan. What printers are available depends.
Login screen : The Login screen cou. Country: Select your country from t. Use RFC compliant v alues: Uns. Ticket printers are used together w.
There is one important parameter to. The choice of the variable part dep. You must define the Data source. Amadeus Laser Paper: when you tick. Finishing dialog Figure PP. These icons are normally permanentl. Terminal address statistics since l. Figure Netcheck main window The. This functionality is available onl. Communication Adapter errors text t.
Output modules errors text Extended. Security Warnings and Error text Co. A dial-up connection will behave as. Extended embed settings. You have already flagged this document.
Thank you, for helping us keep this platform clean. The editors will have a look at it as soon as possible. Self publishing. Share Embed Flag.
TAGS printer configuration amadeus configurator server isdn output settings communication webconf extranets support. Carbon 4. Braun, C. Wohl- 5. Braun 5. All Rights reserv ed Microsoft is a registered trademark of Microsoft Corporation. Documentation formatting. Minor modifications. Update Screenshots. Little changes in layout.
Webconf package list adapted. Dependencies to Automatic Update version actualized. New Webconf configuration values. Chapter MODA added. Screenshots updated to PP 5. Description of fields in the FTP dialog added. Description of fields in the ODBC dialog added.
Description of fields in the Ecoprint dialog added. Description of fields in the BCKD dialog added. Description of standard formatter sub dialog added. Functional overview of MODA mechanism added. Marienbader Platz 1 Bad Homburg Germany 5. O the r little modifications in formatting and sentence structure. R formatter 80 4.
Installation, configuration and troubleshooting sections will allow the users to get a better understanding of the application. It will be distributed by help of Amadeus Automatic Update. What version will be installed, depends on the configuration in the Webconf database for details refer to chapter 3.
From PP 2. From PP 3. From PP 4. The first version was distributed in as a single user process for driving a single printer. Later on modifications were made to drive new printers and several printers simultaneously. Next steps were to allow printing from several hosts simultaneously on the same printer if needed and to support additional devices, like a keyboard for reading electronic debit cards.
During the years a mechanism for updating the Pro Printer software was implemented and adapted to use Amadeus Automatic Update. This should be implemented in future PP releases. These files are used by Mainsrv and Comadapt in case of communication problems with the Security Gateway. Please note, that this file are created by the PP 4. With a single version the development, quality assurance, software distribution and support will be simplified. Pro duct enhancements and bug fixes are available for all markets at the same time.
Never the less a market specific characteristic could be set up. This concern the devices allow to configure in a country, the language of Pro Printer and the configuration program, country specific functions like links to the documentation and chain customer specific settings. Fur the r the Pro Printer specific settings done in the Webconf configuration panel are retrieved. For this Automatic Update version 2.
Due to the fact that the software download is done by help of Amadeus Automatic Update and the available ATIDs are given by Webconf or the Security Gateway, the re is no dependency to the Internet Explorer installed on the machine.
This could be done by calling the Security Gateway registration portal or within the Pro Printer Configurator. This migration will be triggered while installing the new Pro Printer version. The printer certificates migration does not remove the certificates from your machine, so that in case the migration should fail, Pro Printer would still be able to use the se certificates to au the nticate the devices. If the registration fails with the following error: It means that ei the r the CID is already active it was already installed on the same or ano the r PC or the certificate is revoked, in which case a new CID should be provided to the user.
To make client support easier, and for information purposes only, the ATID also appears as plain text in the device configuration file. In addition to the au the ntication that looks for the ATID present inside the encrypted file in the list returned by the Security Gateway, Pro Printer also checks that the ATID in the device configuration file matches the one in the encrypted file.
If this is not the case, the Communication Adapter will exit and an error message is inserted in its log file. So be careful not to delete the encrypted file as well as not to modify the ATID in the configuration file. Here the au the ntication is still performed using the printer certificate, like in the former versions of Pro Printer : 1.
IP server, and used afterwards during the connection negotiation with it. The security process checks the certificate validity with a comparison of the Certificate Authority that has issued the client certificate, with the Amadeus Certificate Authority. Based on a database, it defines the Amadeus software configuration an office should have. It allows vendors to control the software distribution and upgrades by obtaining detailed, regular and accurate data on installed Amadeus software. All o the r options could be selected or deselected.
These packages include different options used in the major markets and defined according to the different Pro Printer version used before. Select the level Vendor, Office Group, Office or Certificate first, where the settings should be activated for. The settings are used to preallocate Pro Printer configuration variables and to adapt the appearance of the Configurator and the links to Pro Printer programs shown on the desktop and the Windows Start menu.
In the PP Configurator both tokens are shown, whereby the airline ID token has higher priority and is used for building the printer list. The settings done in Webconf are a preconfiguration. All fields could be edited if not running the Configurator in Expedient mode. Variable Variant should be used for changing the look too, if different styles are needed after releasing a new Pro Printer version.
The parameters for updating the look must be installed by help of the MODA mechanism the n. Currently this is not supported by DDIP and must not be used. The following values must be configured to activate MODA. The component names must be separated by a comma the n.
Fur the r Polish plk or Czech csy could be selected. When PP is started or runs for more the n 12 hours, it retrieves the Webconf settings and builds the trigger file for the unattended configuration PpAutoConfigParams. When values are changed, comparing with the normal or unattended configuration done earlier, the PP Configurator is started and executes an unattended configuration. There is no check by Webconf, if the settings are valid and do not cause troubles.
With an improper setting you could cut off Pro Printer for the whole market. The printer list is build for each available device in dependence of the printer type and the country code. Fur the r all o the r parameters from section Configuration described below and the CountryID and Language from the section General are used for the unattended configuration. Existing printer configurations are maintained equal the y are created by an unattended or by a normal configuration.
Please note, that the configuration settings are taken from ano the r Webconf server, when changing the URL from production to test system or vice versa after restarting Pro Printer. This could cause unexpected behaviors, if different values are configured.
Ports , and 80 are supported by the load balancer 1a. This value must be set to 0, when no backup DDIP server is configured. KeepAliv eValue This token specifies, what interval in minutes should be used by Pro Printer comadapt. These messages are used to avoid a disconnection of the IP line. An inappropriate time interval could cause an increased telecommunication bill for the customer. If this token and the corresponding token in comadapt. OfficeInfo This token may contain the name of the office maximum 25 characters.
The Office Info is set to the name of the PC the n. The airline code has higher priority the n the country code and is used by Pro Printer for registration at the DDIP server. Fur the r the printer list is switched to the list defined for this airline and not more fore the country e. They are not more started when the Amadeus Pro Printer services comes up, but when a user is logged in to the PC an appropriate entry in the Autostart folder of each user is created for this the refore the name AutostartAll.
Running an amaprt instance under user account allows the access to a network printer or a network drive for AIR transfer. This could only be done by preparing the trigger file PpAutoConfigParams. If the default configuration does not meet the requirements of the market, send a request to the Pro Printer development team please. In principle an individual list could be set up for each country and airline.
The link to the configuration wizard is not added in France. It could also be used for testing o the r servers manually. Show creates the corresponding icon or folder. Hide removes the corresponding icon or folder. The meaning of tokens Show configurable and Hide configurable could be changed by entries in file startpro.
These tokens must be added manually if needed, because the Configurator of PP 5. Only token CallConfigurator is used yet. In case of configuring an office, office group or on vendor level no care must be taken, because all CIDs of this level will get the same settings.
Here an example: Exe1 and Exe2 refer to Autoupdatetool1. This includes settings done in Pro Printer configuration files, links to Pro Printer components created on the desktop or program folder and to execute functions for diagnostic purposes. Here an example of rework. Here is a token for every supported parameter. The value for every token consists of several actions separated by white space. A sub routine is defined by ano the r token again comprising some actions or sub routines.
Every build in action has a Boolean return value. If one action returns false the execution of complete list is interrupted. All the actions must be written in lower case letters. They define the details of shortcut creation and removal. Please note that the Rework program has about 60 different functions. This is particularly necessary when updating from PP 2. Configuration files just having an ini-structure could be update by help of evalbpi.
The used addresses and the TCP port from the D. IP server is ok. IP routing is correct. Improved support for m4a files. Export individual tracks from the Tracks menu. If you need even more power and functionality, then please take a look at Amadeus Pro.
Amadeus attempts to make an internet connection at startup! What the heck? Occasionally, Amadeus makes an http query to see whether a new version is available. What happens is exactly the same as what happens when you click on this link and this link i. If you are concerned about this or choose not to believe what I say, you can disable version checking in the Updates section of the Amadeus Pro preferences.
Is there a manual for Amadeus Pro? Select the menu item Amadeus Pro Help You can also download the manual here. I can not open m4p files purchased on the Music Store with Amadeus, why? Apple decided to forbid third-party applications the access to m4p files. One workaround is to play the files in iTunes and to use Jack to record the output from iTunes. Another workaround is to burn the file on an Audio CD and to open it from there.
What is an RIAA curve? In general, vinyl recordings are engraved with reduced bass levels and increased treble levels. The filter RIAA available from Filters in the Effect menu allows to compensate this filter in order to reproduce vinyl recordings in the correct way.
New in 2. Improved QuickTime and mp4 movie files support, including the preservation … Improved support for m4a files. But make sure, that the. If you want an information dialogue after every print job you have initiated, please tick into this checkbox. Before every print job is send to Windows printer spooler, a dialogue box comes up with the text. This has a pure information message when you use a laser printer.
Because you do not use manifold. DIN A4 blank paper is pulled out automatically out the paper tray. P P le le a a se se n n o o te te , that this checkbox is relevant for laser printers only. It makes no sense to use it with matrix. For almost every voucher you can set a default how many copies you want to print out. Some of the m,. Where you can change the default, you have the choice to define the amount of vouchers for every. When you tick in this checkbox – before every print job starts – the standard Microsoft printer.
Here you can decide how many copies you want to print out possible only with laser. Many laser printer manufacturers define the allocation of the printer trays differently ex factory. So we. This field is for information purposes. It shows, what printer is configured to use for Ecoprint by default. When you have activated a , all enlisted vouchers in the table below are clickable.
Amadeus Laser Paper: when you tick here you activate the voucher print on Amadeus Laser. This means original, copy1 and copy2 will be printed out on one DIN A4 blank paper —. Now you can. Column Lo o g g o o Co Co n n fig fig u u ra ra tio tio n n – for this item you have to look in a special configuration.
The tool maybe. Please note that the configuration program. Selecting a printer and a driver model. The driver model should be taken from a similar printer. This will reduce the amount of work. Presumably most forms will fit and only some critical forms with a lot print. This button is shown only, when a matrix printer is selected. Additional manuals giving more details about Ecoprint and the Logo configuration are available under. This dialog is used to configure the directories for storing the back office data receiving from the.
Amadeus Germany Ticketing system. A directory could be entered or selected, by double click a line in. An individual directory could be selected for ever kind of the four different data types.
The MCB could be enabled or disabled. Please note, that a special keyboard driver will be installed when activating. A reboot of the PC is necessary to activate this. The state of the driver and the MCB could be checked by pressing the test button:. This is used for printing from external. The CIDs known in Webconf must be registered, before the y can be used.
This could be done by help. By clicking on. A connection to the Amadeus Germany database — Portevo server – will be established and a list of.
When this works. The migrated CIDs could be configured. The migration must be executed once only. An installation. It guides the user step by step through the configuration and.
When configuring the connection to the DDIP server an automatic check of the connection. Or by clicking on button shown in the menu bar of the Configurator. Existing settings will be maintained and not more overwritten as in Pro Printer 4. The mechanism to select a printer and an interface is the same as in the PP Configurator printers be. As in the Configurator. A system has to be provided that allows maintenance of files, which are subject to changes depending.
The files are stored in a central repository on an Amadeus server and are accessed. The software on a client PC is able to retrieve valid versions of a file by the. With Moda over AU it is possible to maintain and keep up to date a list of files — herein called file objects.
It also supports packages. These are groups of files which will be updated. Moda supports files which are stored in zip archives. Moda gets the current time from the server by sending a request to the host.
It the n determines the offset in seconds between the current PC time and the host time, and stores this. Fur the r decisions made by Moda which regard also the current time are.
Every day the re is a download of a Meta file version. This Meta file refers. These Meta. The Meta files are structured in a hierarchical order. The root. Meta file is the files. In the files. The package files the mselves are structured like the files. Every day after the download of the Meta files the list of files is processed and for each file it is tested.
If not, it will be downloaded from the. To avoid server overload the exact download times are calculated from the ATID using a hash algorithm. This algorithm should ensure that download times of single clients are spread over a time range.
Triggered by the event StartCopy due to a windows message the file objects are copied to the ir destination. These rules also describe a time period. Instead of copying the rules may stipulate, that the files have to be.
They can also tell to execute the file after copying. File object can also be packages or archives. Packages are actual Meta files. They are not copied, but. Moda will process the m recursively and treats the file objects contained in the re. Archives contain several files. They are not unpacked automatically.
They are unpacked due to o the r. Pro Printer must be restarted twice,. Once all the printers have been configured, you can test your configuration by activating the. Amadeus Pro Printer service. This could be done:. The service and amaprt user processes are re started automatically when running the Configurator in.
The Amadeus Pro Printer service and the Amaprt user processes are re started automatically when running. Stopping of Amadeus Pro Printer should be performed via the associated links and not by using the.
Call RPC Locator and must be started after the se. It is configured in the properties. The Pro Printer system service is starting Mainserv. Webconf database. This action maybe calls the Configurator, if auto configuration was enabled in. The list of the starting output printer modules is. IP Server. It can handle Pro xy communication and authorization. Following Pro xy protocols are supported:. It multiplexes the communication of several printer modules, by determining the service type and dispatching.
This is the very heart of the Pro Printer. TN module configured the re is one instance of AmaPrt started. It exchanges printer messages. The different behaviour required by various printer types and types of file output is achieved by several. The registration of the several modules at the central systems is different:. IP server at the Global Core the D. IP server send request. Amaprt can connect to external printing applications like Docuprint and Ecoprint used in the Amadeus.
The DLLs write the re log information into the same log file as the AmaPrt instance to which the y are. DLL used for showing unsolicited messages on the screen for Amadeus Germany only. Docuprint is. The Ecoprint. The Ecoprint module starts printing as soon as a print message is in the local queue. Ecoprint is. When Amadeus Pro Printer is started, several icons appear in the Windows taskbar:. The control panel is used to display formated error messages received via. In the example above, seven Pro Printer instances are running, as well as the Communication Adapter.
These icons are normally permanently present, even if you are not connected or not working on. When clicking on an icon, the related process window is opened: Pro Printer Communication adapter. This window provides detailed information on the adapter or the instance. The icon color can change according to the connection status and activity:. A green icon indicated that the connection to the Central System is operational. The terminal is.
A red icon indicates that the connection to the Central System is out of order. It is impossible to. A blue icon indicates that data are currently exchanged with the Central System. When positioning the mouse pointer over this icon, the text of the connection status is displayed. It can. As stated before, when clicking on the icon, the user accesses to the Communication Adapter window. It provides detailled information on the connection to the Central System.
The Pro Printer instance icon indicates the current status of the different modules of the Pro Printer. System through the communication adapter. This is called the input module. The colours of the different symbols allow knowing the general status of each module:.
When all the colors are green, the printer is operational and ready to print. When the printer icon is blue, the re is data exchanged with the Central System. When the network symbol is red, the output is ready but the network is out of order.
When the printer output is red, the printer is not ready to print. This can be due to an incorrect. When all the symbols are red, both the network and the printer are not operational.
In case of problem, Amadeus Pro Printer provides several diagnostic methods and powerful status indicators.
This chapter is an advanced description of Amadeus Pro Printer modules and supposes that the reader. The Communication Adapter component handles the communication of all Pro Printer instances with. This connection is automatically established when. In case of connection loss, the adapter attempts to automatically re-connect. The Communication Adapter window is got by clicking on the taskbar icon of the Communication.
It provides information on the global connection with the print server DDIP server and is divided into. A description of the fields in this dialog is given in the following chapters. No action. Pro Printer closes the connection. Pro Printer ignores the invalid. If this message does not dis- address of the Print Server. If it fails, check.
This section provides information on all the data exchanged between all the printers configured on a. This part contains the last error, warning and eventually informative messages raised by the communication. The messages are provided in real time in a circular trace window containing up to.
This main menu option activates some events to be sent to the Web Print Serv ices when trouble. It is mandatory to activate the option so that the Help Desk can perform a remote maintenance on Pro. Printer in Write mode to update the configuration remotely for example. Starting from the version 2.
This window is accessed by clicking on the taskbar icon of the instance. The possible values for the module status are the following:. Input status connection to the Central System through the Communication Adapter. Adapter and the Central System — Pro Printer is waiting. The Output status shows the state of communication with the printer:. This part contains information related to the connection to the Central System through the Communication. This part contains the last error, warning and eventually informative messages raised by this instance.
The messages are provided in real time in a circular trace window containing up to lines. Note that all messages logged by a given Pro Printer instance may be viewed:.
The device name is provided in the title of the. This option unloads the current device. It must be used very carefully. The loading and unloading. Note: Actions on the Trace Settings are not saved in the device configuration and are lost when the.
To check the synchronisation. Note: in the standard case, the first bin is the only one to be configured to support coupons with stock. O the rwise, it can be used to check the current ribbon status:. If YES, the n it is necessary to correct the jam into the printer before. Remove the printed coupons before printing new tickets.
The right part of the window gives information on software version currently residing into the printer,. On Windows platforms, messages are also logged into Windows Event Log. It is possible to view the m. Access the detailed message by double clicking on the message line. The prefix in square brackets indicates. The message is the same as the one logged into the Pro Printer log file. Warning: The Ev ent Log is filled quite soon when logging informativ e message.
Therefore, the debug. Here in a summary, giving for each component the tool that can be used to view the messages raised. The Network diagnostic Tool Netcheck is an additionally tool for checking the network. It checks the. Pro Printer operation, configuration and installation and the server for remote access by the help desk.
Netcheck can be called from the Windows. Netcheck is made up with several tabs for the Amadeus Selling platform applications and Amadeus. Pro Printer. The main tab shows the overall results. The colours in the small boxes have the following significance:. Detail results from the applications can be found in separate tabs.
Do you accept PayPal payments? Amadeus attempts to make an internet connection at startup! What the heck? Occasionally, Amadeus makes an http query to see whether a new version is available. What happens is exactly the same as what happens when you click on this link and this link i.
If you are concerned about this or choose not to believe what I say, you can disable version checking in the Updates section of the Amadeus Pro preferences. Is there a manual for Amadeus Pro? Select the menu item Amadeus Pro Help You can also download the manual here. I can not open m4p files purchased on the Music Store with Amadeus, why? Apple decided to forbid third-party applications the access to m4p files. One workaround is to play the files in iTunes and to use Jack to record the output from iTunes.
Another workaround is to burn the file on an Audio CD and to open it from there. What is an RIAA curve? In general, vinyl recordings are engraved with reduced bass levels and increased treble levels. The filter RIAA available from Filters in the Effect menu allows to compensate this filter in order to reproduce vinyl recordings in the correct way. New in 2.
Amadeus pro 2.5.1 free
They are stored in the ComAdapter. It also supports packages. If the A. When the default values are not sufficient, advanced dialogs similar to the Prtcfg ones giving the possibility to modify the m. You must define the Data source. Input status connection to the Central System through the Communication Adapter.
Amadeus pro 2.5.1 free
With Moda over AU it is possible to maintain and keep up to date a list of files amadeua herein amadeus pro 2.5.1 free file objects. Must be enabled вот ссылка if and only if:. If the re is the requirement, that this instance runs every time. You can force the installation of Pro Printer on the client machine at any time you. Printer development team please. An individual bin setup is not necessary for ATB printers used in the French market. This token specifies, what language should be used for Ecoprint forms please note, that only few forms.